To Configure the Report Time-Out
When you have to run a report that takes a long time to complete (for example, a General Ledger report that covers multiple periods), the report can time out before it finishes. To avoid this error, you can increase the report time-out value. By default, the report time-out is set to 300 seconds.
CAUTION:
Make sure that all users of your website are warned about the site
restart so that they can save all documents.
To Configure the Report Time-Out
- Open the web.config file for the site instance. Usually it is located in %Program Files%\MYOB Acumatica\<instance name>, where <instance name> is the name of the application instance website.
- In the file, find the following line, where ... represents the other
parameters, which depend on your website
settings.
<add name="PXSqlDatabaseProvider" type="PX.Data.PXSqlDatabaseProvider, PX.Data" ... />
- Add the
reportQueryTimeout
parameters to the line and specify the report timeout time (in seconds).<add name="PXSqlDatabaseProvider" type="PX.Data.PXSqlDatabaseProvider, PX.Data" ... reportQueryTimeout="600" />
- Save the web.config file, which automatically restarts the website.